Metal Tube Rotameter

  • Diameter:DN15-DN150
  • Range ratio:10:1 (DN≤100),5:1 (DN>100)
  • protection:IP65
  • Viscosity:≤250 mPa.s
  • Medium Temperature:-80℃~250℃
Share With:
  • Overview
  • Technical Data
  • Inquiry
Operating principle:

Float flow meter is made up of flow sensor and flow indicator. Float is placed vertically inside of conical measuring tube and can freely move up and down along the conical tube owing to hydrodynamic effects.A high-performance permanent magnet is set inside float, by this way the magnetic field around permanent magnet will change along with the float moving up and down.When fluid keeps a stable flow value and float locates in a dynamic balance state in position, the magnetic field around permanent magnet keeps constant also.The magnetic signal will be transmitted in non-contact form by means of the flow Indicator mechanically connected to conical tube. In another word,the indicator is able to detect and process flow value of liquid by magnetic drive system and finally the corresponding flow rate value can be read from the scale on site. Also it can indicate outputs as standard electrical signal (4-20)mA / hart communication protocol.

 


 


 
certificate






 

 
 Specifiation

Measuring Medium

Liquid, gas, steam etc

Environment Temperature

-25~+100, High Temperature Type:300

Accuracy

Normal type:±2.5%, high accuracy type:±1.5%

Medium Viscosity

DN15:≤5mPa.s ≤30mPa.s;

DN25:≤250mPa.s;

DN50-150:≤300mPa.s

Flow Range Ratio

10:01

Power Supply

24VDC,3.6V lithium battery power

Power voltage influence

≤±0.1%F.S

Load Influence

≤±0.1%

Max Working Pressure

DN15~DN50:4.0MPa; DN80~DN150:1.6MPa

Pipe Connection

Flange,Thread,Quick coupling

Shell

Aluminum Alloy

Protection Class

IP65,IP67

Explosion Proof

ExiaIICT1~T6

 

  Selection Table

Selection Table:  Model   PHLZ Z-15-H1-R4-M7-S-T

Indicator 
Type

Local Indicator

Z

 

 

 

 

 

 

LCD Indicator With Ouput

D

Norminal 
Caliber

DN15

15

DN25

25

DN40

40

DN50

50

DN80

80

DN100

100

DN150

150

Structure

Bottom-Top

/

Left-Right (Horizontal)

H1

Right-Left (Horizontal)

H2

Side-Side

AA

Bottom -Side

LA

Thread Connection

S

Quick Coupling Connection

M

Body 
Material

304SS

R4

316SS

R6

316LSS

R6L

Hastelloy C

Hc4

Titanium

Ti

Liner F46(PTFE)

F

Indicator 
Type

Linear Indicator

M7

Nonlinear Indicator(Local Indicator Display Instataneous Flow)

M9

Combination 
Function

24VDC;Remote Transfer 4~20mA Standard Current Signal

S

24VDC;Remote Transfer 4~20mA,Local LCD Display Instantaneous & Accumulative Flow

Z

Local Lithium Battery Power ;Local LCD Display Instantaneous & Accumulative Flow

D

Added 
Function

Measuring Tube With Thermal Preservation / Heat Insulation Jacket

T

Measure Medium Temperature Higher Than 120C

HT

 

   Flow Range Table

Diameter
(mm)

Working 
Number

Flow Range

Pressure Loss kpa

Water L/h

Air m3/h

Water Kpa

Air

Normal Type

Anti-corrossion

Normal type Anti-corrossion type

Normal Type

Anti-corrossion

15

1A

2.5~25

--

0.07~0.7

6.5

-

7.1

1B

4.0~40

2.5~25

0.11~1.1

6.5

5.5

7.2

1C

6.3~63

4.0~40

0.18~1.8

6.6

5.5

7.3

1D

10~100

6.3~63

0.28~2.8

6.6

5.6

7.5

1E

16~160

10~100

0.48~4.8

6.8

5.6

8

1F

25~250

16~160

0.7~7.0

7

5.8

10.8

1G

40~400

25~250

1.0~10

8.6

6.1

10

1H

63~630

40~400

1.6~16

11.1

7.3

14

25

2A

100~1000

63~630

3~30

7

5.9

7.7

2B

160~1600

100~1000

4.5~45

8

6

8.8

2C

250~2500

160~1600

7~70

10.8

6.8

12

2D

400~4000

250~2500

11~110

15.8

9.2

19

40

4A

500~5000

300~3000

12~120

10.8

8.6

9.8

4B

600~6000

350~3500

16~160

12.6

10.4

16.5

50

5A

630~6300

400~4000

18~180

8.1

6.8

8.6

5B

1000~10000

630~6300

25~250

11

9.4

10.4

5C

1600~16000

1000~10000

40~400

17

14.5

15.5

80

8A

2500~25000

1600~16000

60~600

8.1

6.9

12.9

8B

4000~40000

2500~25000

80~800

9.5

8

18.5

100

10A

6300~63000

4000~40000

100~1000

15

8.5

19.2

150

15A

20000~100000

--

600~3000

19.2

--

20.3

Inquiry >>