Radar Level Transmitter
- Application:Solid particles, Powder
- Frequency:26 GHz
- Measurement Precision: ±10mm
- Signal Output:(4 ~ 20) mA/HART
- Measuring Range:30m

Datum measurement: Screw thread bottom or the sealing surface of the flange.
Note: Make sure the radar level meter the highest level cannot enter the measuring blind area (Figure D shown below).
Features
♦ Small antenna size, easy to install; Non-contact radar, no wear, no pollution.
♦ Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.
♦ Serious dust environment on the high level meter work has little effect.
♦ A shorter wavelength, the reflection of solid surface inclination is better.
♦ Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.
♦ The measuring range is smaller, for a measurement will yield good results.
♦ High signal-to-noise ratio, the level fluctuation state can obtain better performance.
♦ High frequency, measurement of solid and low dielectric constant of the best choice.

.jpg)


|
Suitable for |
Solid particles,Powder |
|
Explosion-proof |
Exia IIC T6 Ga |
|
Measuring Range |
30 meters |
|
Frequency |
26 GHz |
|
Temperature: |
-40℃ ~ 250℃ |
|
Measurement |
±10mm |
|
Process Pressure |
-0.1 ~ 4.0MPa |
|
The signal Output |
(4 ~ 20) mA/HART (Two |
|
The Scene Display |
Four digital LCD |
|
Shell |
Aluminum |
|
Connection |
Thread, Flange |
|
Protection Grade |
IP67 |
| License | ||||||||
| P | Standard (Non-explosion-proof) | |||||||
| I | Intrinsically safe (Exia IIC T6 Ga) | |||||||
| G | Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga) | |||||||
| Process Connection / Material | ||||||||
| G | Thread G1½″A / Stainless Steel 304 | |||||||
| N | Thread 1½″ NPT / Stainless Steel 304 | |||||||
| B | Flange DN80 / Stainless Steel 304 | |||||||
| C | Flange DN100 / Stainless Steel 304 | |||||||
| D | Flange DN125 / Stainless Steel 304 | |||||||
| E | Flange DN150 / Stainless Steel 304 | |||||||
| F | Flange DN200 / Stainless Steel 304 | |||||||
| H | Flange DN250 / Stainless Steel 304 | |||||||
| M | Flange DN80 / Cardan joint ( Nickel plated carbon steel ) | |||||||
| K | Flange DN100 / Cardan joint ( Nickel plated carbon steel ) | |||||||
| T | Flange DN125 / Cardan joint ( Nickel plated carbon steel ) | |||||||
| Z | Flange DN150 / Cardan joint ( Nickel plated carbon steel ) | |||||||
| W | Flange DN200 / Cardan joint ( Nickel plated carbon steel ) | |||||||
| V | Flange DN250 / Cardan joint ( Nickel plated carbon steel ) | |||||||
| Y | Special Custom-tailor | |||||||
| Antenna Type / Material | ||||||||
| B | Horn Antenna Φ46mm / Stainless Steel 304 | |||||||
| C | Horn Antenna Φ76mm / Stainless Steel 304 | |||||||
| D | Horn Antenna Φ96mm / Stainless Steel 304 | |||||||
| Seal Up / Process Temperature | ||||||||
| V | Viton / (-40~150) ℃ | |||||||
| K | Kalrez / (-40~250) ℃ | |||||||
| Electronic Unit | ||||||||
| 2 | (4~20) mA / 24V DC / Two wire system | |||||||
| 3 | (4~20) mA / 24V DC / HART two wire system | |||||||
| 4 | (4~20) mA / 220V AC / Four wire system | |||||||
| 5 | RS485 / Modbus | |||||||
| Shell / Protection Grade | ||||||||
| L | Aluminum / IP67 | |||||||
| G | Stainless Steel 304L/ IP67 | |||||||
| Cable Line | ||||||||
| M | M 20x1.5 | |||||||
| N | ½″ NPT | |||||||
| Field Display/The Programmer | ||||||||
| A | Belt | |||||||
| X | Without | |||||||